Operator’ s Manual MODELS: SID851A/250SSID851A/250S-BSID851W/250SSID851W/250S-BSID851A/250S-BCSID851W/250S-BC208--230/115V, 60HZ, 1PHSPIRAL ICEMAKERâD
7 90914BEVERAGE SYSTEM“B” models contain beverage faucets only and must be supplied with cold product from any remote cold plate orrefrigerated soda f
890914123456788 7 6 5 4 3 2 1COLD PLATEPRIMARY REGULATORSOPTIONAL FORDIET ORROOT BEERCARBONATORFILTEROPTIONALPRESSUREREGULATORWATERSUPPLYCO2TANK15-50
990914FIGURE 6. BEVERAGE SYSTEM SCHEMATIC -BC MODELS123456788 7 6 5 4 3 2 1COLD PLATEPRIMARY REGULATORSOPTIONAL FORDIET ORROOT BEERCARBONATORFILTEROPT
1090914OPERATING INSTRUCTIONSA temperature sensing control bulb located in the storage hopper starts and stops the ice making process inresponse to ic
11 90914L1CCTP5208-230 / 115V, 1PH,(4 WIRE SYSTEM)COMPRESSORC2STARTRELAYSTART CAPSTOP /RUNLPSHPSBIN T’STATRUN CAP5CCL2NCOMPRESSORCONTRACTORHARVEST MOT
1290914YELBRNPURBLKREDORNREDBRNYELREDREDYELBLUELPSFUSE 1-1/4 AMPTIME DELAYAGITATORMOTOR CAPCLEANICE MAKERRUNRUNSTOPPUSH TOFLUSHBRNBLKYELBLKBLKFILLVALV
13 90914FIGURE 9. REFRIGERATION SCHEMATIC
1490914MAINTENANCEREGULAR BASIS (or as required)Cleaning of the ice maker is recommended on a regular basis not only for sanitary reasons, but also to
15 909146. Push manual water fill switch and fill evaporator with water (approximately 5 seconds).7. Put the “Clean/Run” switch in the “clean” positio
16909142. Slide the cold plate cover back. (Remove shipping tape and discard).3. Remove any debris from the drain trough and spring. Check that drain
i 90914TABLE OF CONTENTSPageGENERAL INFORMATION 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .DE
17 90914TROUBLESHOOTING GUIDEThe following pages contain troubleshooting charts designed to aid an experienced service person in diagnosingany operati
1890914STARTDOES UNITOPERATE?ISICE MAKERO.K.?ISDISPENSERO.K.?ISBEVERAGESYSTEMO.K.?DONENO OPERATION OF ANYCOMPONENT.GO TO 1.ICE MAKER ABNORMAL.DISPENSE
19 909141. TOTALLY INOPERATIVEPOWERPRESENT ATREAR JUNCTIONBOX?NONONONOYESYESYESYESISSUPPLY FUSEBLOWN (OR C/BTRIPPED)?CHECK FOR LOOSE CONNECTIONOR BROK
2090914NOYES2. ICE MAKER PROBLEMDOESICE MAKEROPERATE?GO TO 2.AIS ICEPRODUCED?DOESCOMPRESSORRUN?ISICE ONEVAPORATOR?GO TO 2.DGO TO 2.B GO TO 2.CIS ICEPR
21 90914YES2.A ICE MAKER PROBLEMNOISHOPPERFULL?RUN/STOPSWITCH?PUT SWITCH INRUN POSITION.NORMAL SHUTOFF ONBIN THERMOSTAT.IS BINTHERMOSTATOPEN?ISWATERLE
2290914YES NO2.B COMPRESSOR INOPERATIVEISLINE VOLTAGEWITHIN ± 10%OF NAMEPLATEVOLTAGE?CHECK VOLTAGEPROBLEMS IN 1.ISTHERMALPROTECTOROPEN?ISCONTACTORPULL
23 90914YES NO2.C NO ICE ON EVAPORATORISHARVESTTIMERRUNNING?ISEVAPORATORCOLD?ISWATER LEVELNORMAL?ISHOT GAS SOLENOIDENERGIZED?CHECKREFRIGERATIONSYSTEM.
2490914YESNO2.D FROZEN EVAPORATORISAMBIENT ABOVE60°F?ISVOLTAGE WITHIN±10%?CHECK VOLTAGE ITEMS IN 1.DISCONNECT PROBE WIRE FROMCONDUCTIVITY CONTROL.DOES
25 90914YESNO2.D (CONT’D)1. CHECK ADJUSTMENT OF TIMER CAM#3. (HARVEST MOTOR)2. CHECK TIMER SWITCH #3.3. CHECK HARVEST MOTOR CAPACITOR.4. CHECK HARVEST
2690914YESNO2.E LOW ICE PRODUCTIONISWATER LEVELNORMAL?ISWATER TEMP.HIGH?ISAMBIENT TEMP.HIGH?ISICE THIN?CHECK WATER ITEMS IN 2.A.NORMAL EFFECT. INSTALL
ii90914TABLE OF CONTENTS (cont’d)LIST OF TABLESPageTABLE 1. SPECIFICATIONS 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
27 90914YES2.F POOR ICE QUALITYNOYESISICE CLOUDY?ISICE SOFT?1. CHECK AIR PUMP.2. CHECK ADJUSTMENT OF TIMER CAM #4. (WATERPUMP)3. CHECK TIMER SWITCH #4
2890914YES3. DISPENSER PROBLEMNODOESAGITATORROTATE?1. CHECK MOTOR CAPACITOR.2. CHECK TIMER SWITCH #5.3. CHECK AGITATOR MOTOR.ISVOLTAGE ATSOLENOID103-1
29 90914YES4. BEVERAGE SYSTEM PROBLEMNOISONE OR MOREFAUCETSINOPERATIVE?1. CHECK WIRING CONNECTIONS TO IN-OPERATIVE FAUCETS.2. REPLACE INOPERATIVE FAUC
3090914MAINTENANCE/ADJUSTMENT PROCEDURESTHERMOSTAT ALTITUDE ADJUSTMENTSIMPORTANT: Adjust the bin thermostat setting only if storage hopper over fill i
31 90914ICE THICKNESS ADJUSTMENTWARNING: Do not adjust ice thickness probe unless all other problem causes have beenevaluated.1. Open the hinged servi
3290914HARVEST TIME ADJUSTMENTWARNING: Disconnect electrical power to the unit before servicing the timer in theelectrical box.1. Disconnect power to
33 9091410AFIGURE 10. HARVEST TIMER
3490914PARTS LISTDESCRIPTION PART NUMBERSAir Cooled Water CooledDispenser Components 250 250 “BC” 250 250 “BC”Gate Slide 21491 21491 21491 21491Depres
35 90914PARTS LIST (CONT’D)DESCRIPTION PART NUMBERSAir Cooled Water CooledRefrigeration Components 250 250 “BC” 250 250 “BC”Compressor 60678 60678 606
36Manual numberIMI CORNELIUS INC.ONE CORNELIUS PLACEANOKA, MN. 55303--6234TELEPHONE (800) 238--3600FACSIMILE (612) 422--3232TECH SVC 1-800-535-4240WAR
1 90914GENERAL INFORMATIONDESCRIPTIONThe Remcor S.I.D. (Spiral Ice Maker/Dispenser) is a unique, self-contained, counter top style unit that automati-
CORPORATE HEADQUARTERS:Remcor Incorporated500 Regency DriveGlendale Heights, IL 60139708. 980.6900
290914INSTALLATION INSTRUCTIONSUNPACKING INSTRUCTIONS1. With the unit upright, carefully remove the shipping crate. Inspect for shipping damage and re
390914IMPORTANT: To ensure proper ice maker operation and also to reduce the frequency of water-relatedservice problems, a water filter should be inst
4909146045 7/845 1/813 1/416 1/42 1/4 148 15/16 2 1/220 1/2124 2 1/2291 1/2AIR DISCHARGE GRILLCONDENSER WATER OUT3/8-NPT (WATER COOLED ONLY)CONDENSER
5 9091415 7/8-IN. 14-IN.2 3/4-IN.10 1/2-IN.16-IN.32 1/2-IN.36-IN.27 11/16-IN.32-IN.2 1/8-IN.UNIT OUTLINE FRONT3/8 DIA.NOTE: Shaded area indicates open
69091427 11/16-IN. 3 1/16-IN.32-IN.14 1/8-IN.11 1/4-IN.36-IN.10 1/2-IN.16-IN.19 5/8-IN. 5 7/8-IN.1/2 DIA.NOTE: Shaded area indicates opening inbottom
Kommentare zu diesen Handbüchern