Ice Frost Operators Manual
Publication Number: M620919596OPR - 6 - © 2004, IMI Cornelius Inc.
FILTER CLEANING Alarm
A filter cleaning alarm will activate when the unit is running hot due to insufficient internal air circulation.
When this occurs a Filtr message will appear on the touch pad LED display readout and an intermittent
audible tone will also sound to alert the operator of this condition.
The Filtr message will appear when the alarm activates (a beeping sound every 4-5 seconds). To
determine the condition that caused the alarm and correct problem, see list of conditions below:
SYSTEM OVER TEMPERATURE Alarm
A system over temperature alarm will activate as a safety precaution when the unit has overheated to
protect the compressor.
The system automatically goes to OFF status where the compressors operations is stopped, while
augers will keep working to avoid forming ice blocks.
When this occurs an Err message will appear on the touch pad LED readout accompanied by a
continuous buzzer sound to alert the operator of this condition.
When this alarm activates, turn OFF all switches. Then determine the condition. (See Filter Cleaning
Alarm Section for Conditions and Corrective Actions).
ICE FROST GENERIC (PRE-MIX)
WARRNING: If the unit runs out of product, is turned off and turned back on without a new
(full) product tank installed the sensor will look for product for 4 minutes. During this 4
minute period CO
2
will be pumped into the air.
Condition Corrective Action
The filter is dirty and needs to be cleaned. Clean and replace filter following instructions
(Removing and Cleaning Filter).
The unit is positioned too close to a wall or
other object restricting air flow and causing
the machine to run at a higher temperature.
Reposition unit to maximize ventilation space
(Installation Instructions).
The filter is not properly installed. Properly install filter (Removing and cleaning fil-
ter).
The unit has been installed near a heat
source, such as a coffee machine, ice maker
or cold beverage machine which expels hot
air from its vents, causing the machine to run
at a high temperature (installation near a
heat source should be avoided).
Reposition unit to maximize ventilation space.
Switch the machines main switch to the ON position (1).
Put the switch (A) into the ON position (1) see Figure 5,
switch A. Controls the flow of the product in the bowls.
The machines bowls will now fill up until the maximum level
is reached.
Continue with start up operations.