2.1 Miscellaneous CONCENTRATE Tips
SLJ Units
If the concentrate causes a false refill light, the refill circuit can be
bypassed (jumped). Jumper the two probes just above the dispense-flush
lever.
QLT Units
QLTs usually use 5 to 1 concentrate which can look thawed in the bag but
still be semi-frozen. Concentrate that is too thick to flow properly may
cause a false refill light because the syrup may not have filled the tube.
When there is no concentrate in the tube, the pump motor runs with no
drag. The concentrate sensor measures current draw on the motor and
assumes that since there is no concentrate in the tube that the concentrate
supply is empty.
3. SETTING RATIOS
A refractometer or hydrometer must be used to measure the post-mix ratio.
Ratios are sometimes set by taste but this is not recommended.