4. MECHANICAL
At least once a year the concentrate pumps should be checked, cleaned, and the pump tub-
ing replaced.
4.1 Concentrate Pump Disassembly:
1. See Installation And Service Manual for pump platform removal procedure.
2. Remove four thumb screws,
housing cover, and impeller.
3. Remove and replace clamps and pump
tubing with new ones (pump tubing and
clamps kit p/n 4509B).
4. Clean components and check that
the rollers spin freely.
Thumb
Screws
Rotor
Assembly
Housing
Clamps
Pump Hose
Impeller
Rollers
SYSTEM DETAILS