1
CLASSIC 1000
REMOTE COOLER
CONTENTS
1. Introduction............................................................. 1
2. Siting and Installation Air Cooled Model
2.1 Siting.............................................................. 2
2.2 Siting & Installation Diagram........................ 2
2.3 Installation .................................................... 3
3. Siting and Installation Water Cooled Model
3.1 Siting.............................................................. 4
3.2 Siting & Installation Diagram........................ 4
3.3 Installation .................................................... 5
4. Maintenance Instructions
4.1 Air Cooled Model .......................................... 7
4.2 Water Cooled Model ..................................... 7
5. Fault Finding
5.1 Air Cooled Model .......................................... 8
5.2 Water Cooled Model ..................................... 9
6. Parts List
6.1 Air Cooled Model ........................................ 11
6.2 Water Cooled Model ................................... 13
6.3 Discharge Unit ............................................. 14
7. Theoretical Throughput Capacity ......................... 15
8. Selection Chart...................................................... 16
9. Wiring Diagrams
9.1 Air Cooled Model ........................................ 17
9.2 Water Cooled Model ................................... 18
1. INTRODUCTION:
IMI Cornelius has a highly versatile range of Classic
Remote Coolers, to suit a variety of applications.
There are 2 basic models:
Air Cooled Classic 1000 *
Water Cooled Classic 1000 *
For each of these, a lid format can be selected with a 3
stage top mounted, water recirculation pump, giving a
nominal, dead end pressure of 1.8 bar (26 psi).
Cassette coils are available, with various length options,
depending upon the quantity and type of product to be
dispensed. There is a choice of, short, long and super
long coils, to give a variety of dispense temperatures. A
maximum of 14 short or long coils can be incorporated.
Where super long coils are required, a maximum of 6
may be used. Any coil spaces not required should be
filled with coil blanks.
Both cooler types have ice bank and temperature
controlled water bath thermostats, which can be selected
according to the operating conditions.
The Air Cooled model will dissipate heat to its
surroundings from the fridge plant and should be
located in a well ventilated area, as close to the chilled
cellar as possible.
The Water Cooled model has a fully sealed refrigeration
system in the base unit. Heat is dissipated via a water/
glycol mixture to an exterior wall mounted Discharge
Unit. The coolant is pumped via a Recirculation Pump
which is mounted in the base unit. The Water Cooled
model can be sited in a chilled cellar, with minimal heat
output.
* The 1000 suffix in the product name indicates the
maximum theoretical number of pints which can be
served in a 1 hour period without a marked increase
in product temperature. It does not allow for heat loss
in the python and other assemblies.