Cornelius 322 Spezifikationen Seite 23

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 60
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 22
Xtreme Ice Training Manual
TP00952
October 17, 2005
18
LED INDICATORS
The LEDs are board circuit indicators. If the LED in the functional board circuit is complete, check component.
Example: Contactor does not energize and LED is “ON”, board circuit is OK. Check contactor, coil, leads,
& connections.
Yellow:
S Evaporator switch(s) (proximity)
S Delay (located on the electrical box front).
Green:
S Water dump valve
S Compressor contactor
S Water Pump
S Hot Gas Valve
S Condenser Fan (cycles on & off with fan)
S Fill Valve
Red:
S Error (located on the electrical box front).
S Ice thickness Adjustment.
Refer to flash codes for control and system diagnostics. Add the flash codes before status indicators (See Figure
11).
Error LED
Delay LED
Red
Yellow
FIGURE 11
STATUS INDICATOR
Green LED Condenser Fan
Yellow LED Left Water Curtain
Green LED Hot Gas Valve
Green LED Water Pump
Yellow LED Right Water Curtain
Green LED Compressor Contactor
Red LED Error
Green LED Dump Valve
Green LED Fill Valve
Yellow LED Delay
Red LED Ice Thickness Adjustment