HIGH CONDENSER TEMPERATURE WARNING AND SHUTDOWN
1. If the condenser temperature rises above 160_F, the machine shuts down.
2. While shut down, the WARNING LED flashes 1 time at 4–second intervals.
3. If the condenser temperature falls below 110
_F, the machine goes into a secondary startup cycle.
4. If the condenser temperature rises above 160
_F again, the machine shuts down again.
5. While shut down, the WARNING LED flashes 1 time at 4–second intervals.
6. If the condenser temperature falls below 110
_F again, the machine goes into another secondary
startup cycle.
7. If the condenser temperature rises above 160_F again, the machine shuts down.
8. While shut down, the ERROR LED flashes 1 time at 4–second intervals.
9. The machine will not run until the power is cycled OFF and then ON.
Possible Causes
1. Ambient temperatures above 100_F.
2. Fan motor failure.
3. Plugged condenser.
4. No water flow (water–cooled units only).
OPEN CONDENSER THERMISTOR SHUTDOWN
1. If the condenser temperature thermistor is open, the machine shuts down.
2. While shut down, the ERROR LED flashes 8 times at 4–second intervals.
3. The machine will not run until the power is cycled OFF and then ON.
Possible Causes
1. Thermistor wire removed.
2. Thermistor failure.
WATER INLET WARNING
1. If the water pan does not fill at a given rate during the water fill cycle, the machine shuts down.
2. While shut down, the WARNING LED flashes 5 times at 4–second intervals.
3. If the water level eventually reaches a given level, the machine goes into a freeze cycle.
Possible Causes
1. Low inlet water pressure.
2. Water fill valve failure.
3. Plugged water fill valve screen.
FAILED WATER SYSTEM SHUTDOWN
1. If the water pan does not fill to a given level, the machine shuts down.
2. While shut down, the ERROR LED flashes 5 times at 4–second intervals.
3. The machine will not run until the power is cycled OFF and then ON.
Possible Causes
1. Pressure tube disconnected or cut.
2. Leak in water pan.
3. Water pan cap removed.