TP00952
November 26, 200120
SAFETY
SAFETY FEATURES
1. Water Fill Time Out
2. Maximum Freeze Time Out
3. Harvest Time Out
4. Bin Full Delay
5. Low Condenser Temperature Delay
6. High Condenser Temperature
7. Open Condenser Thermistor
FLASHING CODE FOR SELF DIAGNOSTICS
Delay LED “Yellow” Error LED “Red”
1 High condenser Temperature Delay 1 High Condenser Temp. Shut Down
2 Water Fill Time Out Delay 2 Water Fill Time Out Shut Down
3 Failed Harvest Delay 3 Failed Harvest Shut Down
4 Maximum Freeze Time Out Delay 4 Maximum Freeze Time Out Shut Down
6 Low Condenser Temperature Delay 6 Low Condenser Temperature Shut Down
7 Open Thermistor Shut Down
8 End of Clean Cycle Shut Down
WATER FILL TIME OUT
1. During the fill cycle if the water level does not reach the maximum level in 4 minutes the machine
goes into a delay sequence.
2. After each delay, the machine restarts at the secondary start up.
3. The sequence continues as follows:
S Fill try, 30 min delay, fill try, 30 min delay, fill try, 2 hr delay.
S Fill try, 30 min delay, fill try, 30 min delay, fill try, 2 hr delay.
S Fill try, 30 min delay, fill try, 30 min delay, fill try, 2 hr delay.
S Fill try, 30 min delay, fill try, 30 min delay, fill try, 2 hr delay.
S Fill try, 30 min delay, fill try, 30 min delay, fill try, shut down.
4. During the delay times, the DELAY LED flashes 2 times at 4 second intervals.
5. Once the machine reaches shut down position, all outputs turn off.
6. At the shut down time, the ERROR LED flashes 2 times at 4 second intervals.
7. The machine will not run until the power is cycled.
8. The delay sequence resets after each successful harvest.
Possible Causes
1. Low inlet water pressure
2. Fill valve failure
3. Plugged fill valve screen
4. Pressure tube disconnected or cut
5. Pressure sensor failure
6. Leak in water pan
7. Water pan cap removed