Cornelius I Series Spezifikationen Seite 11

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 54
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 10
TP00952
November 26, 20016
DISPENSER INSTALLATION
1. Order the proper cuber/dispenser adaptor kit. This package include gasket material, a hold-down
bracket, and bin stat kit (contact service provider for more information).
2. RTV applications (See Figure 3). If the ice bin is full, new ice will not be able to drop. Instead it
blocks the evaporator curtain open and no additional ice is made. This new ice may start to melt and
the resulting liquid can leak out of the joint between the ice maker and bin. To prevent this problem,
seal the joint with food grade silicon sealant.
FIGURE 3
3. Install Bin stat, Part No. 630000408 (See Bin Stat Kit Instructions).
Figure 4 is an example of a typical electical and plumbing connection.
AIR-COOLED MODELS
WATER-COOLED MODELS
Electrical Service Line
Manual Disconnect
Switch
STRAIN RELIEF
MUST BE USED
Water Filter
Shut-Off Valve
Dump
Valve
Drain
Tube
Bin Drain
Tube
*Air Gap 4”
“minimum”
Electrical Service Line
Manual Disconnect Switch
Shut-Off Valve
Water Filter
Shut-Off Valve
Condenser Water Inlet
Dump Valve
Drain Tube
*Air Gap 4”
“minimum”
Bin Drain
Tube
Condenser Water
Drain Tube
Strain Relief
must be used
Floor Drain
Floor Drain
FIGURE 4
* An air gap of at least twice the diameter of the water supply inlet plus a minimum of 1” (25 mm) must
exist between the floor drain and drain tube.
NOTE: Leave all panels on the cuber until it is in place on the bin.