Cornelius I Series Spezifikationen Seite 26

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 54
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 25
TP00952
November 26, 2001 21
MAXIMUM FREEZE TIME OUT
1. At the beginning of the prechill cycle, the microprocessor starts a timer.
2. If the timer reaches 50 minutes before a harvest cycle can be initiated, the machine enters a delay
sequence.
3. After each delay, the machine restarts at the secondary start up.
4. The delay sequence continues as follows:
S Freeze try, 30 min delay, freeze try, 30 min delay, freeze try, 2 hr delay,
S Freeze try, 30 min delay, freeze try, 30 min delay, freeze try, 2 hr delay,
S Freeze try, 30 min delay, freeze try, 30 min delay, freeze try, 2 hr delay,
S Freeze try, 30 min delay, freeze try, 30 min delay, freeze try, 2 hr delay,
S Freeze try, 30 min delay, freeze try, 30 min delay, freeze try, shut down.
5. During the delay times, the DELAY LED flashes 4 times at 4 second intervals.
6. Once the Machine reaches shut down position all out puts turn off.
7. At the shut down time, the ERROR LED flashes 4 times at 4 second intervals.
8. The machine will not run until the power is cycled.
9. The delay sequence resets after each successful harvest.
Possible Causes
1. Water pump failure
2. Low refrigerant charge
3. Leak in refrigerant lines
4. Compressor failure
5. Hot gas valve leaking
6. Dirty evaporator
HARVEST TIME OUT
1. If the microprocessor does not recognize all proximity switch circuits opening 4 minutes after the hot
gas valve opens during the harvest cycle, the machine enters a delay sequence.
2. After each delay, the machine restarts at the secondary start up.
3. The delay sequence continues as follows:
S Harvest try, 30 min delay, harvest try, 30 min delay, harvest try, 2 hr delay.
S Harvest try, 30 min delay, harvest try, 30 min delay, harvest try, 2 hr delay.
S Harvest try, 30 min delay, harvest try, 30 min delay, harvest try, 2 hr delay.
S Harvest try, 30 min delay, harvest try, 30 min delay, harvest try, 2 hr delay.
S Harvest try, 30 min delay, harvest try, 30 min delay, harvest try, shut down.
4. During the delay times, the DELAY LED flashes 3 times at 4 second intervals.
5. Once the machine reaches shut down position all out puts turn off.
6. At the shut down time, the ERROR LED flashes 3 times at 4 second intervals.
7. The machine will not run until the power is cycled.
8. The delay sequence resets after each successful harvest.
Possible Causes
1. Hot gas valve failure
2. Low refrigerant charge
3. Prox. Switch
4. Compressor failure
Seitenansicht 25
1 2 ... 21 22 23 24 25 26 27 28 29 30 31 ... 53 54

Kommentare zu diesen Handbüchern

Keine Kommentare